Kodak KY0730485 All in One Printer User Manual


 
Matchprint Professional Server for DocuColor 12 Printer/Copier – Quick Start
2002 Kodak Polychrome Graphics. All Rights Reserved.
14
left corner of the test form.
Important Note on Calibrating the Spectrocam: Each Spectrocam
needs to be calibrated against its own unique White Reference Target before
taking measurements. The Spectocam and its White Reference have
matching serial numbers. For additional information, please see the
Spectrocam user documentation.
3. Touch the green sensor and move the device slowly across the first row.
When you complete the first row, reposition the Spectrocam over the first
patch of the second row and touch the green sensor again to begin measuring
the second row. Continue in this fashion until all rows are read.
Patches are read from left to right in a slow, steady manner. The color
patches appear on the screen as they are measured. It should take
approximately 6 to 8 seconds to completely scan one row.
If you move too slowly or too rapidly, patches are not read correctly. Within
the calibrate dialog an X appears on any patch that is miss-read. If this
happens, reposition the device on the first patch of that row and touch the
sensor to start the patch reading of that row again. The Instruction box at the
top of the window will indicate any action you must take regarding
measurement readings.
To read the last two rows, you will need to move the test form up so the
Spectrocam rests on the black scanner plate.
Note: The Spectrocam times out after 10 minutes of inactivity. Instructions
appear directing the user to restart the calibration process.
If the calibration is successful, the following message appears: "The calibration
process was successful. You may now calibrate another media."