C: Networking and Security
EDS Device Servers User Guide 149
(Since the remote port was not specified in the ATDT command, the remote port
defined under Connect mode is used.)
Entering ATDT 28.150 causes the EDS to assume the first two octets in the IP
address and connects to the remote IP address 192.168.28.150, port 10001.
Entering ATDT 150 causes the EDS to assume the first three octets and
connects to the remote IP address 192.168.16.150, port 10001.
Entering ATDT 28.150:10012 causes the EDS to assume the first two octets in
the IP address and connects to the remote IP address 192.168.28.150, port
10012.
Note: If you add 10012 after the IP address segment, port 10012 is used instead
of the port defined in Connect mode.
By default, the +++ characters are not passed through the connection. To pass them
through the connection, enable Echo Pluses on the Tunnel - Modem Emulation page
(see Tunnel – Modem Emulation Page on page 65).