Lenovo 2491 Laptop User Manual


 
Diagnostic Error Code FRU/Action
170-199-XXX Voltage Sensor(s) test failed, cause
unknown
1. See “Undetermined problems” on page 66.
2. Flash the system and re-test. See “Updating
(ashing) the BIOS from a disc” on page 180
.
3. Replace component under function test.
170-250-XXX 170-251-XXX Voltage Sensor(s) Voltage
limit error
1. AC/DC power adapter
2. System board
170-254-XXX Voltage Sensor(s) Voltage Regulator
Module error
1. Voltage Regulator Module (VRM)
2. Microprocessor
3. System board
175-000-XXX Thermal Sensor(s) Test Passed
No action
175-0XX-XXX Thermal Sensor(s) failure
1. Flash system
2. System board
175-195-XXX Thermal Sensor(s) Test aborted by user
Information only Restart the test, if necessary
175-196-XXX Thermal Sensor(s) test halt, error threshold
exceeded
1. Press F3 to review the log le.
2. Restart the test to reset the log le.
175-197-XXX Thermal Sensor(s) test warning
1. Make sure the component that is called out is
connected and/or enabled. See Chapter 6 “Using the
Setup Utility program” on page 41.
2. Re-run test.
3. Replace the component that is called out in warning
statement.
4. Replace the component under test.
175-198-XXX Thermal Sensor(s) test aborted
1. If a component is called out, make sure it is
connected and/or enabled .
2. Flash the system and re-test. See “Updating
(ashing) the BIOS from a disc” on page 180
.
3. Go to “Undetermined problems” on page 66.
175-199-XXX Thermal Sensor(s) test failed, cause
unknown
1. See “Undetermined problems” on page 66.
2. Flash the system and re-test. See “Updating
(ashing) the BIOS from a disc” on page 180.
3. Replace component under function test.
175-250-XXX 175-251-XXX Thermal Sensor(s) limit error 1. Check fans
2. Check AC/DC power adapter voltages.
3. Microprocessor
4. System board
185-000-XXX Asset Security Test Passed
No action
185-XXX-XXX Asset Security failure
1. Flash system
2. System board
185-278-XXX Asset Security Chassis Intrusion 1. Assure Asset Security Enabled
2. C2 Cover Switch
3. System board
201-000-XXX System Memory Test Passed
No action
Chapter 7. Symptom-to-FRU index 61