Diagnostic Error Code FRU/Action
025-00X-XXX 025-01X-XXX IDE interface failure
1. IDE signal cable
2. Check power supply voltages
3. Reseat IDE signal cable
4. IDE device
5. System board
025-027-XXX IDE interface Conguration/Setup error
1. IDE signal cable
2. Flash the system. See “Updating (ashing) BIOS
from a disc” on page 560
3. Reseat IDE signal cable
4. IDE device
5. System board
025-02X-XXX 025-03X-XXX 025-04X-XXX IDE Interface
failure
1. IDE signal cable
2. Check power supply
3. Reseat IDE signal cable
4. IDE device
5. System board
025-195-XXX IDE interface Test aborted by user Information only Re-start the test, if necessary
025-196-XXX IDE interface test halt, error threshold
exceeded
1. Press F3 to review the log le
2. Re-start the test to reset the log le
025-197-XXX IDE interface test warning
1. Make sure the component that is called out is
connected and/or enabled. See Chapter 6 “Using
the Setup Utility” on page 43
2. Re-run test
3. Replace the component that is called out in warning
statement
4. Replace the component under test
025-198-XXX IDE interface test aborted
1. If a component is called out, make sure it is
connected and/or enabled. See Chapter 6 “Using
the Setup Utility” on page 43
2. Flash the system and re-test. See “Updating
(ashing) BIOS from a disc” on page 560
3. Go to “Undetermined problems” on page 69
025-199-XXX IDE interface test failed, cause unknown
1. Go to “Undetermined problems” on page 69
2. Flash the system and re-test. See “Updating
(ashing) BIOS from a disc” on page 560
3. Replace component under function test
030-000-XXX SCSI interface Test Passed
No action
030-00X-XXX 030-01X-XXX SCSI interface failure 1. SCSI signal cable
2. Check power supply
3. SCSI device
4. SCSI adapter card, if installed
5. System board
58 ThinkCentre Hardware Maintenance Manual