Numeric error codes
Table 2. Numeric error codes
Symptom or error
FRU or action, in sequence
0175
Bad CRC1, stop POST task—The EEPROM checksum is
not correct.
System board.
0176
System Security—The system has been tampered with.
1. Run BIOS Setup Utility, and save the current
setting by pressing F10.
2. System board.
0177
Bad SVP data, stop POST task—The checksum of the
supervisor password in the EEPROM is not correct.
System board.
0182
Bad CRC2. Enter BIOS Setup and load Setup
defaults.—The checksum of the CRS2 setting in the
EEPROM is not correct.
1. Run BIOS Setup Utility. Press F9, and Enter to
load the default setting. Then save the current
setting by pressing F10.
2. System board.
0185
Bad startup sequence settings. Enter BIOS Setup and
load Setup defaults.
1. Run BIOS Setup Utility. Press F9, and Enter to
load the default setting. Then save the current
setting by pressing F10.
0187
EAIA data access error—The access to EEPROM is failed.
System board.
0188
Invalid RFID Serialization Information Area.
System board.
0189
Invalid RFID conguration information area—The
EEPROM checksum is not correct.
System board.
0190
Critical low-battery error
1. Charge the battery pack.
2. Battery pack.
0191
System Security—Invalid Remote Change requested.
1. Run BIOS Setup Utility, and then save current
setting by pressing F10.
2. System board.
0192
System Security— Embedded Security hardware tamper
detected.
System board.
0193
RF antenna has been removed
Enter the BIOS Setup Utility supervisor password.
0194
The computer has been carried through a security gate
Enter the supervisor password.
0195
Security hardware tamper detected
1. Enter BIOS Setup Utility by entering supervisor
password, and select Password Security Chip
Clear Security Chip to clear this error.
2. Security chip.
3. System board.
0196
Security hardware removed
1. Enter BIOS Setup Utility by entering supervisor
password, and select Password Security Chip
Clear Security Chip to clear this error.
2. Security chip.
3. System board.
0197
Invalid remote change requested.
The remote conguration for the security chip has
failed. Conrm the operation and try again.
Chapter 4. Related service information 51