Diagnostic Error Code FRU/Action
015-035-XXX USB port Reset condition detected 1. Remove USB device(s) and re-test
2. System board
015-036-XXX USB port Register error System board
015-040-XXX USB port IRQ failure
1. Run setup and check for conicts
2. Flash the system. See “Updating (ashing) BIOS
from a disc” on page 560
3. System board
015-195-XXX USB port Test aborted by user
Information only Re-start the test, if necessary
015-196-XXX USB port test halt, error threshold exceeded
1. Press F3 to review the log le
2. Re-start the test to reset the log le
015-197-XXX USB port test warning
1. Make sure the component that is called out is
connected and/or enabled. See Chapter 6 “Using
the Setup Utility” on page 43
2. Re-run test
3. Replace the component that is called out in warning
statement
4. Replace the component under test
015-198-XXX USB port test aborted
1. If a component is called out, make sure it is
connected and/or enabled. See Chapter 6 “Using
the Setup Utility” on page 43
2. Flash the system and re-test. See “Updating
(ashing) BIOS from a disc” on page 560
3. Go to “Undetermined problems” on page 69
015-199-XXX USB port test failed, cause unknown 1. Go to “Undetermined problems” on page 69
2. Flash the system and re-test. See “Updating
(ashing) BIOS from a disc” on page 560
3. Replace component under function test
018-000-XXX PCI Card Test Passed
No action
018-0XX-XXX PCI Card Failure
1. Riser card, if installed
2. System board
018-195-XXX PCI Card Test aborted by user 1. PCI card
2. Information only Re-start the test, if necessary
018-196-XXX PCI Card test halt, error threshold exceeded
1. Press F3 to review the log le
2. Re-start the test to reset the log le
018-197-XXX PCI Card test warning
1. Make sure the component that is called out is
connected and/or enabled. See Chapter 6 “Using
the Setup Utility” on page 43
2. Re-run test
3. Replace the component that is called out in warning
statement
4. Replace the component under test
56 ThinkCentre Hardware Maintenance Manual