Menu item
Submenu item Comments
Easy Conguration Create physical arrays. An array will
automatically become a virtual drive.
New Conguration Clear the existing conguration and
start a new conguration.
View/Add Conguration
View the existing conguration or add a
new conguration.
Clear Conguration Clear the existing conguration.
Congure
Select Boot Drive Select a boot virtual drive.
Initialize
Varies by conguration.
Initialize virtual drives.
Adapter
Set adapter related parameters, such
as rebuild rate, consistency check rate,
auto-rebuild, and so on.
Virtual Drive
Set virtual drive parameters.
Objects
Physical Drive
Set physical drive parameters, such as
creating a hot-spare drive for the virtual
drive, making a failing drive as online,
changing a drive state, and viewing the
specications of a physical drive.
Rebuild
Varies by conguration.
Rebuild physical drive(s).
Check Consistency
Varies by conguration.
Check consistency of virtual drive(s).
Creating, adding, or deleting a RAID array
This topic provides instructions on how to create, add, or delete a RAID array using the LSI Software RAID
Conguration Utility program.
Note: Before you create a RAID array using the LSI Software RAID Conguration Utility program, make sure
that the server meets the required hardware conguration. For example, the server needs to have the
required number of SATA hard disk drives installed and connected to the system board. See “About RAID”
on page 72
for information about the required number of hard disk drives for each RAID level. If you want to
create a RAID 5 array using the LSI Software RAID Conguration Utility program, the server also needs to
have a ThinkServer SATA Software RAID 5 Key installed on the system board. See “Installing or removing the
ThinkServer SATA Software RAID 5 Key” on page 102
.
To create, add, or delete a RAID array using the LSI Software RAID Conguration Utility program, do the
following:
1. Start the LSI Software RAID Conguration Utility program. See “Starting the LSI Software RAID
Conguration Utility program” on page 74.
2. On the main interface of the program, do one of the following depending on your needs:
• If you want to create a RAID array, select Easy Conguration and then follow the instructions on
the screen.
• If you want to add a secondary RAID conguration, select View/Add Conguration and then follow
the instructions on the screen to view the current conguration and add a new conguration.
• If you want to delete the existing RAID conguration, exit the program and back up all your data on
the hard disk drives. After backing up all your data, enter the program main interface and select Clear
Conguration. Select Yes when prompted and follow the instructions on the screen.
76 ThinkServer Hardware Maintenance Manual