Diagnostic error code FRU/Action
020-0XX-XXX PCI interface error 1. PCI card
2. Riser card, if installed
3. System board
020-195-XXX PCI test aborted by user
Information only Re-start the test, if necessary
020-196-XXX PCI test halt, error threshold exceeded
1. Press F3 to review the log le
2. Re-start the test to reset the log le
020-197-XXX PCI test warning
1. Make sure the component that is called out is
connected and/or enabled. See Chapter 6 “Using the
Setup Utility” on page 41
2. Re-run test
3. Replace the component that is called out in warning
statement
4. Replace the component under test
020-198-XXX PCI test aborted
1. If a component is called out, make sure it is
connected and/or enabled. See Chapter 6 “Using the
Setup Utility” on page 41
2. Flash the system and re-test. See “Updating
(ashing) BIOS from a disc” on page 99
3. Go to “Undetermined problems” on page 64
020-199-XXX PCI test failed, cause unknown 1. Go to “Undetermined problems” on page 64
2. Flash the system and re-test. See “Updating
(ashing) BIOS from a disc” on page 99
3. Replace component under function test
020-262-XXXPCI system error 1. PCI card
2. Riser card, if installed
3. System board
025-000-XXXIDE interface Test Passed
No action
025-00X-XXX 025-01X-XXX IDE interface failure
1. IDE signal cable
2. Check power supply voltages
3. Reseat IDE signal cable
4. IDE device
5. System board
025-027-XXX IDE interface Conguration/Setup error
1. IDE signal cable
2. Flash the system. See “Updating (ashing) BIOS
from a disc” on page 99
3. Reseat IDE signal cable
4. IDE device
5. System board
025-02X-XXX 025-03X-XXX 025-04X-XXX IDE Interface
failure
1. IDE signal cable
2. Check AC/DC power adapter
3. Reseat IDE signal cable
4. IDE device
5. System board
025-195-XXX IDE interface Test aborted by user Information only Re-start the test, if necessary
Chapter 7. Symptom-to-FRU index 53