Diagnostic Error Code FRU/Action
001-038-XXX System Extension failure
1. Adapter card
2. System board
001-039-XXX System DMI data structure error 1. Flash the system. See “Updating (ashing) the
BIOS” on page 165.
2. System board
001-040-XXX System IRQ failure 1. Power-off/on system and re-test.
2. System board
001-041-XXX System DMA failure 1. Power-off/on system and re-test.
2. System board
001-195-XXX System Test aborted by user
Information only Restart the test, if necessary
001-196-XXX System test halt, error threshold exceeded
1. Press F3 to review the log le
2. Restart the test to reset the log le
001-197-XXX System test warning
1. Make sure the component that is called out is
connected and/or enabled. See Chapter 6 “Using
the Setup Utility program” on page 39.
2. Re-run test.
3. Replace the component that is called out in warning
statement.
4. Replace the component under test.
001-198-XXX System test aborted
1. If a component is called out, make sure it is
connected and/or enabled. See Chapter 6 “Using
the Setup Utility program” on page 39.
2. Flash the system and retest. See “Updating
(ashing) the BIOS” on page 165.
3. Go to “Undetermined problems” on page 67.
001-199-XXX System test failed, cause unknown 1. Go to “Undetermined problems” on page 67.
2. Flash the system and re-test.
3. Replace component under function test.
001-250-XXX System ECC error System board
001-254-XXX 001-255-XXX 001-256-XXX 001-257-XXX
System DMA error
System board
001-260-XXX 001-264-XXX System IRQ error System board
001-268-XXX System IRQ1 failure 1. Device on IRQ1
2. System board
001-269-XXX System IRQ2 failure 1. Device on IRQ2
2. System board
001-270-XXX System IRQ3 failure 1. Device on IRQ3
2. System board
001-271-XXX System IRQ4 failure 1. Device on IRQ4
2. System board
001-272-XXX System IRQ5 failure 1. Device on IRQ5
2. System board