Diagnostic Error Code FRU/Action
001-038-XXX System Extension failure
1. Adapter card
2. System board
001-039-XXX System DMI data structure error 1. Flash the system. See “Updating (ashing) the
BIOS” on page 165.
2. System board
001-040-XXX System IRQ failure 1. Power-off/on system and re-test.
2. System board
001-041-XXX System DMA failure 1. Power-off/on system and re-test.
2. System board
001-195-XXX System Test aborted by user
Information only Restart the test, if necessary
001-196-XXX System test halt, error threshold exceeded
1. Press F3 to review the log le
2. Restart the test to reset the log le
001-197-XXX System test warning
1. Make sure the component that is called out is
connected and/or enabled. See Chapter 6 “Using
the Setup Utility program” on page 39.
2. Re-run test.
3. Replace the component that is called out in warning
statement.
4. Replace the component under test.
001-198-XXX System test aborted
1. If a component is called out, make sure it is
connected and/or enabled. See Chapter 6 “Using
the Setup Utility program” on page 39.
2. Flash the system and retest. See “Updating
(ashing) the BIOS” on page 165.
3. Go to “Undetermined problems” on page 67.
001-199-XXX System test failed, cause unknown 1. Go to “Undetermined problems” on page 67.
2. Flash the system and re-test.
3. Replace component under function test.
001-250-XXX System ECC error System board
001-254-XXX 001-255-XXX 001-256-XXX 001-257-XXX
System DMA error
System board
001-260-XXX 001-264-XXX System IRQ error System board
001-268-XXX System IRQ1 failure 1. Device on IRQ1
2. System board
001-269-XXX System IRQ2 failure 1. Device on IRQ2
2. System board
001-270-XXX System IRQ3 failure 1. Device on IRQ3
2. System board
001-271-XXX System IRQ4 failure 1. Device on IRQ4
2. System board
001-272-XXX System IRQ5 failure 1. Device on IRQ5
2. System board
48 Hardware Maintenance Manual