Diagnostic Error Code FRU/Action
014-197-XXX Parallel port test warning 1. Make sure the component that is called out is
connected and/or enabled. See Chapter 6 “Using
the Setup Utility program” on page 39
.
2. Re-run test.
3. Replace the component that is called out in warning
statement.
4. Replace the component under test.
014-198-XXX Parallel port test aborted
1. If a component is called out, make sure it is
connected and/or enabled.
2. Flash the system and re-test. See “Updating
(ashing) the BIOS” on page 165.
3. Go to “Undetermined problems” on page 67.
014-199-XXX Parallel port test failed, cause unknown
1. Go to “Undetermined problems” on page 67.
2. Flash the system and re-test. See “Updating
(ashing) the BIOS” on page 165
.
3. Replace component under function test.
014-2XX-XXX 014-3XX-XXX Parallel port failure
1. External parallel device
2. System board
015-000-XXX USB port Interface Test Passed
No action
015-001-XXX USB port Presence 1. Remove USB device(s) and re-test.
2. System board
015-002-XXX USB port Timeout 1. Remove USB device(s) and re-test.
2. System board
015-015-XXX USB port External Loopback failure 1. Remove USB device(s) and re-test.
2. System board
015-027-XXX USB port Conguration/Setup error 1. Flash the system. See “Updating (ashing) the
BIOS” on page 165.
2. System board
015-032-XXX USB port Device Controller failure System board
015-034-XXX USB port buffer allocation failure
1. Reboot the system
2. Flash the system and re-test. See “Updating
(ashing) the BIOS” on page 165.
3. Run memory test.
4. System board
015-035-XXX USB port Reset condition detected 1. Remove USB device(s) and re-test.
2. System board
015-036-XXX USB port Register error System board
015-040-XXX USB port IRQ failure 1. Run the Setup Utility program and check for
conicts.
2. Flash the system. See “Updating (ashing) the
BIOS” on page 165.
3. System board
015-195-XXX USB port Test aborted by user
Information only Restart the test, if necessary.
Chapter 8. Symptom-to-FRU Index 53