Diagnostic Error Code FRU/Action
086-199-XXX Mouse Port interface test failed, cause
unknown
1. See “Undetermined problems” on page 66.
2. Flash the system and re-test. See “Updating
(ashing) the BIOS from a disc” on page 180
.
3. Replace component under function test.
089-000-XXX Microprocessor Test Passed No action
089-XXX-XXX Microprocessor failure
1. Microprocessor(s)
2. System board
089-195-XXX Microprocessor Test aborted by user
Information only Restart the test, if necessary.
089-196-XXX Microprocessor test halt, error threshold
exceeded
1. Press F3 to review the log le.
2. Restart the test to reset the log le.
089-197-XXX Microprocessor test warning 1. Make sure the component that is called out is
connected and/or enabled. See Chapter 6 “Using the
Setup Utility program” on page 41.
2. Re-run the test.
3. Replace the component that is called out in warning
statement.
4. Replace the component under test.
089-198-XXX Microprocessor test aborted
1. Flash the system. See “Updating (ashing) the BIOS
from a disc” on page 180
.
2. Go to “Undetermined problems” on page 66.
089-199-XXX Microprocessor test failed, cause unknown
1. See “Undetermined problems” on page 66.
2. Flash the system and re-test. See “Updating
(ashing) the BIOS from a disc” on page 180
.
3. Replace component under function test.
170-000-XXX Voltage Sensor(s) Test Passed
No action
170-0XX-XXX Voltage Sensor(s) failure
1. Flash system
2. System board
170-195-XXX Voltage Sensor(s) Test aborted by user
Information only Restart the test, if necessary.
170-196-XXX Voltage Sensor(s) test halt, error threshold
exceeded
1. Press F3 to review the log le.
2. Restart the test to reset the log le.
170-197-XXX Voltage Sensor(s) test warning
1. Make sure the component that is called out is
connected and/or enabled. See Chapter 6 “Using the
Setup Utility program” on page 41
.
2. Re-run the test.
3. Replace the component that is called out in warning
statement.
4. Replace the component under test.
170-198-XXX Voltage Sensor(s) test aborted
1. If a component is called out, make sure it is
connected and/or enabled. See Chapter 6 “Using the
Setup Utility program” on page 41
.
2. Flash the system and re-test. See “Updating
(ashing) the BIOS from a disc” on page 180.
3. Go to “Undetermined problems” on page 66.