Lenovo 5214 Computer Hardware User Manual


 
Diagnostic error code FRU/Action
005-031-XXX Video device cable failure
1. Video cable
2. Monitor
3. Video card, if installed
4. System board
005-032-XXX Video device controller failure 1. Video card, if installed
2. System board
005-036-XXX Video register error
1. Video card, if installed
2. System board
005-038-XXX System BIOS extension failure
1. Video card, if installed
2. System board
005-040-XXX Video IRQ failure
1. Video card, if installed
2. System board
005-195-XXX Video test aborted by user
Information only Re-start the test, if necessary
005-196-XXX Video test halt, error threshold exceeded
1. Press F3 to review the log le
2. Re-start the test to reset the log le
005-197-XXX Video test warning 1. Make sure the component that is called out is
connected and/or enabled. See Chapter 6 “Using the
Setup Utility” on page 41
2. Re-run test
3. Replace the component called out in warning
statement
4. Replace the component under test
005-198-XXX Video test aborted
1. If a component is called out, make sure it is
connected and/or enabled. See Chapter 6 “Using the
Setup Utility” on page 41
2. Flash the system and re-test. See “Updating
(ashing) BIOS from a disc” on page 99
3. Go to “Undetermined problems” on page 64
005-199-XXX Video test failed, cause unknown
1. Go to “Undetermined problems” on page 64
2. Flash the system and re-test. See “Updating
(ashing) BIOS from a disc” on page 99
3. Replace component under function test
005-2XX-XXX 005-3XX-XXX Video subsystem error
1. Video card, if installed
2. System board
006-000-XXX Diskette interface Test Passed
No action
006-0XX-XXX Diskette interface error
1. Diskette drive Cable
2. Diskette drive
3. System board
006-195-XXX Diskette interface Test aborted by user Information only Re-start the test, if necessary
006-196-XXX Diskette interface test halt, error threshold
exceeded
1. Press F3 to review the log le
2. Re-start the test to reset the log le
50 Hardware Maintenance Manual