Diagnostic Error Code FRU/Action
006-195-XXX
Diskette interface Test aborted by user
Information only
Re-start the test, if necessary
006-196-XXX
Diskette interface test halt, error threshold
exceeded
1. Press F3 to review the log file
2. Re-start the test to reset the log file
006-197-XXX
Diskette interface test warning
1. If a component is called out, make sure
it is connected and/or enabled
2. Re-run test
3. Replace the component that is called out
in warning statement
4. Replace the component under test
006-198-XXX
Diskette interface test aborted
1. If a component is called out, make sure
it is connected and/or enabled
2. Flash the system and re-test. See “Flash
update procedures” on page 214
3. Go to “Undetermined problems” on page
90
006-199-XXX
Diskette interface test failed, cause unknown
1. Go to “Undetermined problems” on page
90
2. Flash the system and re-test
3. Replace component under function test
006-25X-XXX
Diskette interface Error
1. Diskette drive cable
2. Diskette drive
3. System board
011-000-XXX
Serial port Interface Test Passed
No action
011-001-XXX
Serial port Presence
1. Remove external serial device, if
present
2. Run setup, enable port
3. System board
011-002-XXX
011-003-XXX
Serial port Timeout/Parity error
System board
011-013-XXX
011-014-XXX
Serial port Control Signal/Loopback test
failure
System board
011-015-XXX
Serial port External Loopback failure
1. Wrap plug
2. System board
011-027-XXX
Serial port Configuration/Setup error
1. Run Setup, enable port
2. Flash the system. See “Flash update
procedures” on page 214
3. System board
011-03X-XXX
011-04X-XXX
Serial port failure
System board
Chapter 7. Symptom-to-FRU Index 67