Lenovo 8126 Computer Accessories User Manual


 
Diagnostic Error Code FRU/Action
030-198-XXX
SCSI interface test aborted
1. If a component is called out, make sure
it is connected and/or enabled. See
Chapter 6, “Using the Setup Utility,” on
page 55
2. Flash the system and re-test. See “Flash
update procedures” on page 214
3. Go to “Undetermined problems” on page
90
030-199-XXX
SCSI interface test failed, cause unknown
1. Go to “Undetermined problems” on page
90
2. Flash the system and re-test. See “Flash
update procedures” on page 214
3. Replace component under function test
035-000-XXX
RAID interface Test Passed
No action
035-0XX-XXX
RAID interface Failure
1. RAID signal cable
2. RAID device
3. RAID adapter card, if installed
4. System board
035-195-XXX
RAID interface Test aborted by user
Information only
Re-start the test, if necessary
035-196-XXX
RAID interface test halt, error threshold
exceeded
1. Press F3 to review the log file
2. Re-start the test to reset the log file
035-197-XXX
RAID interface test warning
1. Make sure the component that is called
out is connected and/or enabled. See
Chapter 6, “Using the Setup Utility,” on
page 55
2. Re-run test
3. Replace the component that is called out
in warning statement
4. Replace the component under test
035-198-XXX
RAID interface test aborted
1. If a component is called out, make sure
it is connected and/or enabled. See
Chapter 6, “Using the Setup Utility,” on
page 55
2. Flash the system and re-test. See “Flash
update procedures” on page 214
3. Go to “Undetermined problems” on page
90
035-199-XXX
RAID interface test failed, cause unknown
1. See “Undetermined problems” on page
90
2. Flash the system and re-test. See “Flash
update procedures” on page 214
3. Replace component under function test
071-000-XXX
Audio port Interface Test Passed
No action
74 Hardware Maintenance Manual