Lexmark 259x Printer User Manual


 
Print Position
2-10
Draft document
USAGE NOTES
The default is 1/216 inch. The supported alternative is 1/180 inch and 1/360
inch.
n1 and n2 specify the number of mode bytes contained in this escape
sequence. Normally, n1 is 4, and n2 is 0.
m1 and m2 are ignored.
m3 and m4 set the base units as follows:
Select 1/8" Line Spacing
This command (ESC zero) sets the line spacing at 1/8 inch between each line, which
is 8 lines per inch (lpi).
Select 7/72" Line Spacing
This command sets the line spacing at 7/72 inch between each line, which is 10.3 lpi.
Table 2-3: Set Vertical Unit - m3 and m4 values
m3 m4
UnitDecimal Hexadecimal Decimal Hexadecimal
216 D8 00 00 1/216
180 B4 00 00 1/180
104 68 01 01 1/360
Format ESC 0
Decimal 27 48
Hexadecimal 1B 30
Format ESC 1
Decimal 27 49
Hexadecimal 1B 31