LG Electronics 42VS20 Computer Monitor User Manual


 
74
ENG
ENGLISH
CONTROLLING THE MULTIPLE PRODUCT
25. Off Timer(Repeat Mode/ Time) (Command: f e)
To set the Off Timer(Repeat mode/ Time) function.
Transmission
[f][e][ ][Set ID][ ][Data1][ ][Data2][ ][Data3][Cr]
Data1 00: Repeat Off
01: Repeat Once
02. Repeat Daily
03: Repeat from Monday to Friday
04: Repeat from Monday to Saturday
05: Repeat from Saturday to Sunday
06. Repeat on Sunday
Data2 01 to 17: 00 to 23 Hours
Data3 01 to 3B: 00 to 59 Minutes
* Enter “fe [Set ID] ff” for checking Off Timer(Repeat
mode/ Time) values.
* Check if Time1 and Time2 have been set before
setting this function.
Acknowledgement
[e][ ][Set ID][ ][OK/NG][Data1][Data2][Data3][x]
26. On Timer(Repeat Mode/ Time) (Command: f d)
To set the On Timer(Repeat mode/ Time) function.
Transmission
[f][d][ ][Set ID][ ][Data1][ ][Data2][ ][Data3][Cr]
Data1 00: Repeat Off
01: Repeat Once
02. Repeat Daily
03: Repeat from Monday to Friday
04: Repeat from Monday to Saturday
05: Repeat from Saturday to Sunday
06. Repeat on Sunday
Data2 01 to 17: 00 to 23 Hours
Data3 01 to 3B: 00 to 59 Minutes
* Enter “fd [Set ID] ff” for checking On Timer(Repeat
mode/ Time) values.
* Check if Time1 and Time2 have been set before
setting this function.
Acknowledgement
[d][ ][Set ID][ ][OK/NG][Data1][Data2][Data3][x]
27. On Timer Input (Command: f u)
To set the On Timer Input function.
Transmission
[f][u][ ][Set ID][ ][Data][Cr]
Data 20: AV
40: Component
60. RGB
90: HDMI
70: DVI
C0: DISPLAY PORT
* Check if Time1 and Time2 and On Timer(Repeat
Mode/Time) functions have been set before setting
this function.
Acknowledgement
[u][ ][Set ID][ ][OK/NG][Data][x]
28. Sleep Time (Command: f f)
To set sleep time.
Transmission
[f][f][ ][Set ID][ ][Data][Cr]
Data 00: Off
01: 10 min.
02: 20 min.
03: 30 min.
04: 60 min.
05: 90 min.
06: 120 min.
07: 180 min.
08: 240 min.
Acknowledgement
[f][ ][Set ID][ ][OK/NG][Data][x]
29. Power On Delay (Command: f h)
To set the schedule delay when the power is turned
on(unit: second).
Transmission
[f][h][ ][Set ID][ ][Data][Cr]
Data 00 to 64: 0 to 100sec.
Acknowledgement
[h][ ][Set ID][ ][OK/NG][Data][x]