Chapter 7 Buffer read/write instructions
7 - 8
7.2.2 RPUT instructions
RPUT FUN(233) RPUT Applicable CPU
K200S
K300S
K1000S
Available devices Flag
Instructions
M P K L F T C S D #D Integer
Steps
Error
(F110)
Zero
(F111)
Carry
(F112)
sl ¡
st
¡
S ¡
D ¡ ¡ ¡ ¡* ¡ ¡ ¡ ¡
n
¡
¡
RPUT
SS ¡ ¡ ¡ ¡* ¡ ¡ ¡ ¡
13
¡
Operand setting
Upper
byte
Type of remote special function
module
sl
Lower
byte
Slot number of Fnet module of
self-station
D
Start address of buffer memory
of A/D module of remote
station
Upper
byte
Slot number of remote special
function module
st
Lower
byte
Station number of Fnet remote
module
n Number of words to be read
S
Start address of device at which source
data is stored (self-station)
SS
Device at which the link status
is stored
* Available only when do not use computer link module or data link module
1) Functions
- Write the data of ‘n’ words which start at the device specified as ‘S’ to the block which
begin with the address specified as ‘D’ of buffer memory inside the special function
module of remote station. (station number & slot number is specified as ‘st’) through the
Fnet communication module. Then stores the link status into the device specified as ‘SS’
of self-station.
RPUT sl st S D n SS
Input
condition