LG Electronics PCS100R Server User Manual


 
10
206-4142
Surge Protected
Power Strip
To AC
power
source
ASI-OUT
AC IN
ASI IN
.....
....
SOFTWARE
RESET
NETWORK
POWER
12V / 5A
RS-232
PCS100R
Power Connector
Modulator
ASI IN
PCS100R
ASI OUT
75 ohm
BNC-to-BNC
coaxial cable
Modulator/Upconverter
Power Supply/Cord
PCS100R Power
Supply/Cord
Disconnect Device
The AC mains plug is used as the disconnect device.
The disconnect device must remain readily operable.
Typical modulator/
upconverter unit
PCS100R
Rack Installation (Cont.)
Rack-mount Considerations
A. Elevated Operating Ambient
If installed in a closed or multi-unit rack
assembly, the operating ambient tempera-
ture of the rack environment may be greater
than room ambient. Therefore, consideration
should be given to installing the equipment
in an environment compatible with the maxi-
mum ambient temperature (Tma) specified by
the manufacturer (see “Specifications” infor-
mation in this document).
B. Reduced Air Flow
Installation of the equipment in a rack should
be such that the amount of air flow required
for safe operation of the equipment is not
compromised. Do NOT stack other equipment
on the top of the PCS100R unit.
C. Circuit Overloading
Consideration should be given to the con-
nection of the equipment to the supply circuit
and the effect that overloading of the circuits
might have on overcurrent protection and
supply wiring.
D. Reliable Earthing
Maintain reliable earthing of rack-mounted
equipment. Particular attention should be
given to supply connections other than direct
connections to the branch circuit (e.g. use of
power strips).
E. Mains Outlet Earthing
The apparatus with Class I construction must
be connected to a mains socket outlet with a
protective earthing connection.