System Options 75
5.0 S
YSTEM
O
PTIONS
5.1 General
7KLVýVHFWLRQýGHVFULEHVýRSWLRQVýDYDLODEOHýZLWKýWKHý6HULHVýêííý'7ý836ýLQFOXGLQJýWKHýXVHUýZLULQJý
UHTXLUHPHQWVïý7KHýRSWLRQVýGHVFULEHGýDUHã
‡ ([WHUQDOý0DLQWHQDQFHý%\SDVV
‡ 6OLPð/LQHý'LVWULEXWLRQ
‡ 5HPRWHý6WDWXVý3DQHO
‡ 5HPRWHý&RQWDFWý%RDUG
‡ 56ðëêëý,QWHUIDFHý3RUW
‡6103
‡ 0RGHP
‡6LWH6FDQ
Š
î6LWHPDVWHUý,QWHUIDFH
‡,%0
Š
ý$6îéííý6LJQDOý,QWHUIDFH
‡ 6\VWHPîêåý3RZHUý:DUQLQJý6LJQDO
‡ %DWWHU\ý&LUFXLWý%UHDNHU
‡ '&ý*URXQGý)DXOWý$ODUP
‡ &RPSXWHUý,QWHUIDFHý6\VWHP
‡ 0XOWLð&RPSXWHUý,QWHUIDFHý6\VWHP
‡,%0
Š
ý$6îéííý0XOWLð,QWHUIDFHý6\VWHPï
5.2 Optional External Maintenance Bypass Cabinet
7KHýH[WHUQDOýPDLQWHQDQFHýE\SDVVýFDEL QHWýLVýDýPDWFKLQJ ý FDELQHWýH[WHQVLRQýWKDWýLVýILHOGýLQVWDOOHGý
RQýWKHýULJKWýVLGHýRIýWKHý836ýPRGXOHïý7KLVýFDELQHWýLVýDYDLODEOHýLQýæýV\VWHPýFRQILJXUDWLRQVïý7KHýFRQð
ILJXUDWLRQVýDUHýOLVWHGýLQý7DEOH äï
$OOýFDELQHWVýDUHýVXSSOLHGýZLWKýLQWHUðFDELQHWýZLULQJñýFDV WHUVñýDQGýOHYHOLQJýIHHWïý)URQWýDFFHVVýRQO\ýLVý
UHTXLUHGýIRUýVHUYLFHýDQGýLQVWDOODWLRQïý7KHýFDELQHWýDGGVýëëûýRUýêçûýWRýWKHýULJKWýVLGHýRIýWKHý836ýPRGð
XOHýGHSHQGLQJýRQýZKLFKýFRQILJXUDWLRQýLVýFKRVHQïý5HIHUýWRý)LJXUH ëýWKURXJKý)LJXUH åýDQGý
)LJXUH ëæýWKURXJKý)LJXUH êêï
‡ &DELQHWý,QVSHFWLRQãý5HPRYHýDOOýSDQHOVýDQGýYLVXDOO\ýLQVSHFWýWKHýSK\VLFDOýFRPSRQHQWVñýLQWHUð
QDOýFRQQHFWLRQVñýDQGýFDELQHWýIRUýDQ\ýGDPDJHïý,IýWKHUHýDUHýVLJQVýRIýGDPDJHñýGRýQRWýSURFHHGïý
&DOOý/LHEHUWý&XVWRPHUý6HUYLFHýDQGý6XSSRUWýDW ýìðåííðèéëðëêæåï
Table 9 Optional External Maintenance Bypass Cabinet
Configuration Description
Configuration H
This cabinet includes input, bypass, and load circuit breakers.
Configuration J
This cabinet includes bypass shielded isolation transformer and load circuit breaker.
Configuration K
This cabinet includes bypass shielded isolation transformer with input, bypass, and load
circuit breakers.
Configuration L
This cabinet includes a maintenance bypass switch that provides “make-before-break”
operation to and from maintenance bypass via a single rotary switch without the need for
interlocking schemes.
Configuration N
This cabinet includes a maintenance bypass switch that provides “make-before-break”
operation to and from maintenance bypass via a single rotary switch without the need for
interlocking schemes. Also provides input, bypass, and load circuit breakers.
Configuration P
This cabinet includes a maintenance bypass switch that provides “make-before-break”
operation to and from maintenance bypass via a single rotary switch without the need for
interlocking schemes. Also provides bypass shielded isolation transformer and load circuit
breakers.
Configuration Q
This cabinet includes a maintenance bypass switch that provides “make-before-break”
operation to and from maintenance bypass via a single rotary switch without the need for
interlocking schemes. Also provides bypass shielded isolation transformer with input,
bypass, and load circuit breakers.