i. OSD means that the OSD window is displayed on your monitor for 10 sec. You can modify
this value from 05 sec to 99 sec. Default is 10 sec.
j. SCAN displays the scan duration per channel in Auto Scan Mode. The default SCAN time
is 10 sec., the maximum scan time can be set to 99 sec, it cannot be less then 5 sec.
k. CONSOLE ON/OFF is used to prevent unauthorized use of the console. “CONSOLE ON”
means that any user can access the console. “CONSOLE OFF” (factory default) means that
any user will have to enter the password before getting access. When the password is entered
correctly the CONSOLE status will be set to ON. To lock the console again the status has to be
changed from CONSOLE ON to OFF via OSD. Also if the current CONSOLE state is ON and
you reset the KVM switch, the CONSOLE will be reset to the OFF state.
l. CHANGE PASSWORD is used
to set a new password. The factory
default is 8 digits “00000000”.
To change the password you have
to input the old password and then
type in the new password twice, to
prevent mistyping. The maximum
password length is eight digits.
Make sure you do not forget the
password. Otherwise you will have
to send the KVM Switch to LINDY
for maintenance.
Finally you will see the confirmation
message that the new password is
set.
When you have switched to a certain port on the CPU Switch the keyboard and mouse
commands are directed to the attached computer and its monitor signal is displayed on the
screen.
In this overlay window from the OSD you will see some basic
information for the selected computer / port. The OSD shows
the port number; the status of the attached computer - “”,
to indicate that this computer is online and powered on; and the computer name.
You can close almost any overlay OSD window by simply pressing the ESCAPE key.
ENTER PASSWORD :
ESC : QUIT ENTER :
ENTER NEW PASSWORD :
ESC : QUIT ENTER :
NEW PASSWORD COMPLETE
ESC : QUIT ENTER :
102
SYSTEM 02
RETYPE NEW PASSWORD :
ESC : QUIT ENTER :