LSI 1600 Network Card User Manual


 
MegaRAID Enterprise 1600 Hardware Guide
64
Step 8 Connect Battery Pack,
Continued
Configure Battery Backup
After installing the MegaRAID controller and booting, press <Ctrl> <M>. Choose the
Objects menu. Select Battery Backup. The following menu displays:
Menu Item Explanation
Battery Pack PRESENT will appear if the battery pack is properly installed;
ABSENT if it is not.
Temperature GOOD appears if the temperature is within the normal range. HIGH
appears if the module is too hot.
Voltage GOOD appears if the voltage is within the normal range. BAD
appears if the voltage is out of range.
Fast
Charging
COMPLETED appears if the fast charge cycle is done. CHARGING
appears if the battery pack is charging.
No. of
Cycles
This must be configured. When first installing a battery pack, set the
Charge Cycle to 0. The screen below appears when you select No. of
Cycles. Choose YES to reset the number of cycles to zero.
After 1100 charge cycles, the life of the battery pack is assumed to
be over and you must replace the battery pack.