LSI Series 518 Network Card User Manual


 
Other BIOS Error Messages 8-5
Copyright © 2002 by LSI Logic Corporation. All rights reserved.
8.3 Other BIOS Error Messages
Table 8.3 describes other BIOS error messages, their meaning, and
suggested solutions.
8.4 Other Potential Problems
Table 8.4 describes other potential problems.
Table 8.3 Other BIOS Error Messages
Message Problem Suggested Solution
Following SCSI disk
not found and no
empty slot available
for mapping it
The physical disk roaming
feature did not find the
physical disk with the
displayed SCSI ID. No slot is
available to map the physical
drive. MegaRAID cannot
resolve the physical drives
into the current configuration.
Reconfigure the array.
Following SCSI IDs
have the same data y,
z
Channel x: a, b, c
The physical drive roaming
feature found the same data
on two or more physical drive
on channel x with SCSI IDs a,
b, and c. MegaRAID cannot
determine the drive that has
the duplicate information.
Remove the drive or drives that should not
be used.
Unresolved
configuration
mismatch between
disks and NVRAM on
the adapter
The configuration stored in the
MegaRAID NVRAM does not
match the configuration stored
on the drives.
1. Press a key to run MegaRAID Manager.
2. Select View/Add Configuration from the
Configure menu.
3. Use View/Add Configuration to examine
both the configuration in NVRAM and the
configuration stored on the disk drives.
4. Resolve the problem by selecting one of
the configurations.
Table 8.4 Other Potential Problems
Topic Information
DOS ASPI MEGASPI.SYS, the MegaRAID DOS ASPI manager, uses 6 Kbytes of system
memory once it is loaded.