MaxTech 800 Network Card User Manual


 
10
%Ln Set transmit level to -n dBm Default = 12.(n=0-15)
%M0 Autodetect V.34 and V.FC negotiation signals
%M1 Autodetect V.34 negotiation signals only
%M2 Autodetect V.FC negotiation signals only
%P0 Disable Power-on Auto-connect
%P1 Enable Power-on Auto-connect
%S0 Disable Call-back Security
%S1 Enable Call-back Security with password check
%S2 Enable Password check only
\P=x Stores password x (x = ASCII characters 1 through
127 excluding “?”, maximum 7 characters) into non-
volatile RAM
MNP/V.42/V.42bis Commands
%An Set auto-reliable fallback character to n (n = 0 to 127).
Requires the \C2 setting
%C0 Disable V.42bis/MNP Class 5 data compression
%C1 Enable V.42bis/MNP Class 5 data compression
\A0 64-character maximum MNP block size
\A1 128-character maximum MNP block size
\A2 192-character maximum MNP block size
\A3 256-character maximum MNP block size
\Bn Send a 1/10 second line break to the modem (n = 1- 9).
At normal connect, the default is 3
\C0 Do not buffer data during LAPM/MNP
handshaking
\C1 Buffer all data for 4 seconds, until receiving 200
characters or until a packet is detected
\C2 Do not buffer data; switch to normal mode when
fallback character is detected
\E0 Do not echo data during a normal link
\E1 Echo data during a normal link
\G0 Disable DCE flow control
\G1 Enable DCE flow control
\J0 Disable serial port data rate adjustment (keep high
data rate between DTE and modem, regardless of
modem-to-modem data rate)
\J1 Enable serial port data rate adjustment so serial data
rate automatically adjusts to match the modem-to-
modem data rate