SCANNER CONFIGURATION TO THE HOST SYSTEM
The IS4220 is shipped from the factory pre-programmed to a set of default
parameters. It may be necessary to change the default parameters to match the
host system’s requirements or to enable additional scanner functions. For a list
of possible parameter settings, refer to the Default Settings section of this guide.
Important notes for the -07 and -08, IS4220 USB Interfaces.
The IS4220-07 and the IS4220-08 are pre-programmed for USB
Emulation before leaving the factory. If the recall defaults bar code is
scanned the unit must be re-programmed for USB Emulation before
enabling or disabling any additional features documented in the
programming guide (MLPN 00-02343).
To re-program the unit for USB Keyboard Emulation or USB POS
Emulation refer to the IS4220 USB Addendum (MLPN 00-02044)
for the IS4220 Programming Guide.
To modify the scanner’s default parameters follow the steps below using the bar
codes located in the programming guide (
MLPN 00-02343).
1. Scan the
ENTER PROGRAM MODE bar code to enter programming mode. The
scanner will beep three times.
2. Scan the bar code(s) for the desired parameter(s). The scanner will beep
once.
3. Scan the
EXIT PROGRAM MODE bar code to exit and save the new parameter
settings. The scanner will beep three times.
If during programming there is a need to return the scanner to the
original factory settings, scan the recall defaults bar code in the
programming guide. All settings selected during that session or any
previous sessions are discarded when you scan the recall defaults
code.
Please read the warning above for the IS4220-07 and -08 models
before using the recall defaults bar code.