Milwaukee 2291-20 Scanner User Manual


 
4
5
STUD Mode
In Stud mode, the Sub-Scanner will detect wood or
metal studs and joists behind wall board, wooden
panels, plaster or other non-metallic wall materials.
The Sub-Scanner can not reliably detect studs
behind material of varying densities. Materials
such as carpet, wire metal mesh backing, damp
walls, and stucco may affect readings. Alternating
surfaces, such as thick grout lines or extremely
heavy plaster on drywall, may be detected or show
as metal or studs.
1.Turn on the Sub-Scanner.
2.Select Stud mode.
3.Depth of scan is
defaulted to 0.5"
(standard wallboard
thickness). To
change the depth
of scan (0.5", 1",
or 1.5"), press the
STUD button.
4.Hold the Sub-
Scanner against
the surface and
press the Calibrate
button.
NOTE: The Sub-
Scanner will not
calibrate correctly over studs. To nd a location
without studs, locate an outlet box and move the
Sub-Scanner 6" to either side before beginning
calibration.
5.When SCANNING
is displayed, move
the Sub-Scanner
across the surface.
Keep your free
hand and other
objects at least 6”
(152 mm) away to
avoid false readings.
NOTE: The Sub-Scanner must remain at against
and in contact with the surface during the entire
scan.
6.When a stud is de-
tected, the edge is
displayed. Contin-
ue moving the Sub-
Scanner to detect
the entire stud.
7.When the center
of the stud is de-
tected, both arrows
are displayed.
NOTE: If electric
wires or metal/
pipes are in contact
with the backside of
the wallboard, they
may be identi ed as
a stud.
STUD
CALIBRATING
0.5” DEPTH
STUD
PLACE ON SURFACE TO
CALIBRATE 0.5” DEPTH
PRESS ‘CAL’ TO START
OR ‘STUD’
TO CHANGE DEPTH
STUD
SCANNING...
0.5” DEPTH
STUD
EDGE
STUD
ACCESSORIES
For a complete listing of accessories refer to your
MILWAUKEE Electric Tool catalog or go online
to www.milwaukeetool.com. To obtain a catalog,
contact your local distributor or service center.
WARNING Always remove battery pack
before changing or removing accessories.
Only use accessories speci cally recommend-
ed for this tool. Others may be hazardous.
MAINTENANCE
WARNING To reduce the risk of per-
sonal injury and damage, never immerse your
tool, battery pack or charger in liquid or allow
a liquid to ow inside them.
WARNING To reduce the risk of injury,
always remove the batteries from the tool
before performing any maintenance. Never
disassemble the tool. Contact a MILWAUKEE
service facility for ALL repairs.
Cleaning
Clean dust and debris from tool vents. Keep tool
handles clean, dry and free of oil or grease. Use
only mild soap and a damp cloth to clean the tool
since certain cleaning agents and solvents are
harmful to plastics and other insulated parts. Some
of these include gasoline, turpentine, lacquer thin-
ner, paint thinner, chlorinated cleaning solvents,
ammonia and household detergents containing
ammonia. Never use ammable or combustible
solvents around tools.
Repairs
For repairs, return the tool to the nearest service center
listed on the back cover of this operator's manual.
Maintaining Tool
Keep your tool in good repair by adopting a regular
maintenance program. If the tool does not start
or operate at full power with fully charged batter-
ies, clean the contacts on the battery. If the tool
still does not work properly, return the tool to a
MILWAUKEE service facility for repairs.
FIVE YEAR TOOL LIMITED WARRANTY
MILWAUKEE Test & Measurement Product (including bare tool, battery pack(s) and battery charger) is
warranted to the original purchaser only to be free from defects in material and workmanship. Subject to
certain exceptions, MILWAUKEE will repair or replace any part on this product which, after examination, is
determined by MILWAUKEE to be defective in material or workmanship for a period of ve (5) years* after
the date of purchase. Return of the Test & Measurement tool to the nearest MILWAUKEE Electric Tool
Corporation - factory Service Center, freight prepaid and insured is required. A copy of the proof of purchase
should be included with the return product. This warranty does not apply to damage that MILWAUKEE
determines to be from repairs made or attempted by anyone other than MILWAUKEE authorized personnel,
misuse, alterations, abuse, normal wear and tear, lack of maintenance, or accidents.
*The warranty period for the LITHIUM-ION battery pack that ships with Test & Measurement Product is
two (2) years from the date of purchase. *Alkaline battery that ships with Test & Measurement Product is
separately warranted by the battery manufacture.
*The warranty period for a NON-CONTACT VOLTAGE DETECTOR – 2201 20 or Plumb 2-Beam Plumb
Laser – 2230 20 is one (1) year from the date of purchase.
Warranty Registration is not necessary to obtain the applicable warranty on MILWAUKEE product. The
manufacturing date of the product will be used to determine the warranty period if no proof of purchase is
provided at the time warranty service is requested.
ACCEPTANCE OF THE EXCLUSIVE REPAIR AND REPLACEMENT REMEDIES DESCRIBED HEREIN IS
A CONDITION OF THE CONTRACT FOR THE PURCHASE OF EVERY MILWAUKEE PRODUCT. IF YOU
DO NOT AGREE TO THIS CONDITION, YOU SHOULD NOT PURCHASE THE PRODUCT. IN NO EVENT
SHALL MILWAUKEE BE LIABLE FOR ANY INCIDENTAL, SPECIAL, CONSEQUENTIAL OR PUNITIVE
DAMAGES, OR FOR ANY COSTS, ATTORNEY FEES, EXPENSES, LOSSES OR DELAYS ALLEGED
TO BE AS A CONSEQUENCE OF ANY DAMAGE TO, FAILURE OF, OR DEFECT IN ANY PRODUCT
INCLUDING, BUT NOT LIMITED TO, ANY CLAIMS FOR LOSS OF PROFITS. SOME STATES DO NOT
ALLOW THE EXCLUSION OR LIMITATION OF INCIDENTAL OR CONSEQUENTIAL DAMAGES, SO THE
ABOVE LIMITATION OR EXCLUSION MAY NOT APPLY TO YOU. THIS WARRANTY IS EXCLUSIVE
AND IN LIEU OF ALL OTHER WARRANTIES, WRITTEN OR ORAL. TO THE EXTENT PERMITTED BY
LAW, MILWAUKEE DISCLAIMS ANY IMPLIED WARRANTIES, INCLUDING WITHOUT LIMITATION ANY
IMPLIED WARRANTY OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR USE OR PURPOSE;
TO THE EXTENT SUCH DISCLAIMER IS NOT PERMITTED BY LAW, SUCH IMPLIED WARRANTIES ARE
LIMITED TO THE DURATION OF THE APPLICABLE EXPRESS WARRANTY AS DESCRIBED ABOVE.
SOME STATES DO NOT ALLOW LIMITATIONS ON HOW LONG AN IMPLIED WARRANTY LASTS, SO
THE ABOVE LIMITATION MAY NOT APPLY TO YOU, THIS WARRANTY GIVES YOU SPECIFIC LEGAL
RIGHTS, AND YOU MAY ALSO HAVE OTHER RIGHTS WHICH VARY FROM STATE TO STATE.
This warranty applies to product sold in the U.S.A. and Canada only.
TECHTRONIC INDUSTRIES' warranty is for 5 year since the original purchase date.
This warranty card covers any defect in material and workmanship on this Power Tool.
To make this warranty valid, present this warranty card, sealed/stamped by the distributor or store where you purchased the product, to the
Authorized Service Center (ASC). Or, if this card has not been sealed/stamped, present the original proof of purchase to the ASC.
Call toll-free 1 800 832 1949 to nd the nearest ASC, for service, parts, accessories or components.
Procedure to make this warranty valid
Take the product to the ASC, along with the warranty card sealed/stamped by the distributor or store where you purchased the product, and
there any faulty piece or component will be replaced without cost for you. We will cover all freight costs relative with this warranty process.
Exceptions
This warranty is not valid in the following situations:
a) When the product is used in a different manners from the end-user guide or instruction manual.
b) When the conditions of use are not normal.
c) When the product was modi ed or repaired by people not authorized by TECHTRONIC INDUSTRIES.
Note: If cord set is damaged, it should be replaced by an Authorized Service Center to avoid electric risks.
SERVICE AND ATTENTION CENTER
Rafael Buelna No.1.
Col. Tezozomoc Mexico, Azcapotzalco D.F.
Ph. 01 800 832 1949
IMPORTED AND COMMERCIALIZED BY:
TECHTRONIC INDUSTRIES MEXICO, .S.A. DE C.V.
Av. Santa Fe 481 piso 6, Col. Curz Manca.
CP 05349, Cuajimalpa, D.F.
LIMITED WARRANTY - MEXICO, CENTRAL AMERICA AND CARIBBEAN
Model:
Date of Purchase:
Distributor or Store Stamp: