13. Restart the projector.
Do not turn the power on with the lamp cover removed.
Resetting the lamp timer
14. After the startup logo, open the On-Screen Display (OSD) menu. Go to
the SYSTEM SETUP: Advanced > Lamp Settings menu. Press
MODE/ENTER. The Lamp Settings page is displayed. Press to
highlight Reset lamp timer and press MODE/ENTER. A warning
message is displayed asking if you want to reset the lamp timer. Highlight
Reset and press MODE/ENTER. The lamp time will be reset to '0'.
6. Lift the handle so that it stands up. Use the handle to slowly pull the
lamp out of the projector.
Pulling it too quickly may cause the lamp to break and scatter broken glass
in the projector.
Do not place the lamp in locations where water might splash on it, children
can reach it, or near flammable materials.
Do not insert your hands into the projector after the lamp is removed. If you
touch the optical components inside, it could cause color unevenness and
distortion of the projected images.
7. As shown in the figure, lower the new lamp into the lamp
compartment while aligning the lamp with the holes in the lamp
compartment. Make sure it fits in the projector.
8. Tighten the screw that secures the lamp.
Loose screw may cause a bad connection, which could result in
malfunction.
Do not over tighten the screw.
9. Ensure the handle is fully laid flat and locked in place.
10. Place the lamp protection film supplied with the new lamp on the
lamp compartment.
11. As shown in the figure, replace the lamp cover on the projector.
12. Tighten the screws that secure the lamp cover.
Loose screw may cause a bad connection, which could result in
malfunction.
Do not over tighten the screws.
2
1
2
1