Moxa Technologies 405A SERIES Switch User Manual


 
EDS-408A/405A Series User’s Manual Featured Functions
3-11
NOTE
If you upgrade the firmware of your EDS from Turbo Ring to Turbo Ring V2, but do not reset the
switch to factory defaults, the DIP switches will be set to configure the EDS for a “Turbo Ring”
ring. If you reset the switch to factory defaults, the DIP switches will be set to configure the EDS
for a “Turbo Ring V2” ring.
How to Configure the Turbo Ring DIP Switches
The Turbo Ring DIP Switches are set to the OFF position at the factory.
NOTE
The four DIP Switches are used to configure both the “Turbo Ring”
and “Turbo Ring V2” protocols, depending on which protocol is
active. To select which protocol the EDS will use, start the user
interface software, and then use the left menu to navigate to the
Communication Redundancy page. To use one of the Turbo Ring
protocols for the EDS, select either “Turbo Ring” or “Turbo Ring V2”
in the Redundancy Protocol drop-down box. See the Configuring
“Turbo Ring” and “Turbo Ring V2” section in this chapter for
details.
12
------
MASTER
COUPLER
TURBO
RING
34
The following tables show how to use the DIP switches to configure the EDS for “Turbo Ring” or
“Turbo Ring V2.”
NOTE
DIP switch 4 must be set to the ON position to enable DIP switches 1, 2, and 3. If DIP switch 4 is
set to the “OFF” position, then DIP switches 1, 2, and 3 will all be disabled.
“Turbo Ring” DIP Switch Settings
DIP 1 DIP 2 DIP 3 DIP 4
ON: Enables this EDS
as the Ring Master.
ON: Enables the
default “Ring
Coupling” ports.
ON
: Activates DIP
switches 1, 2, 3 to
configure “Turbo
Ring” settings.
Reserved for future
use.
OFF
: This EDS will
not be the Ring
Master.
OFF
: Do not use this
EDS as the ring
coupler.
OFF
: DIP switches 1,
2, 3 will be disabled.
“Turbo Ring V2” DIP Switch Settings
DIP 1 DIP 2 DIP 3 DIP 4
ON: Enables the
default “Ring
Coupling (backup)”
port.
ON
: Enables this EDS
as the Ring Master.
ON: Enables the
default “Ring
Coupling” port.
ON
: Activates DIP
switches 1, 2, 3 to
configure “Turbo Ring
V2” settings.
OFF: Enables the
default “Ring
Coupling (primary)”
port.
OFF
: This EDS will
not be the Ring
Master.
OFF
: Do not use this
EDS as a ring coupler.
OFF: DIP switches 1,
2, 3 will be disabled.