Moxa Technologies EDS-405A Switch User Manual


 
EDS-408A/405A Series User’s Manual Featured Functions
3-49
Port Event Warning e-mail is sent when…
Link-on The port is connected to another device.
Link-off
The port is disconnected (e.g., the cable is pulled
out, or the opposing device shuts down).
Traffic-Overload
The port’s traffic surpasses the Traffic-Threshold for
that port (provided this setting is Enabled).
Traffic-Threshold (%)
Enter a nonzero number if the port’s
Traffic-Overload setting is Enabled.
Traffic-Duration (sec.)
A Traffic-Overload warning is sent every
Traffic-Duration seconds if the average
Traffic-Threshold is surpassed during that time
period.
NOTE
The Traffic-Overload, Traffic-Threshold (%), and Traffic-Duration (sec) Port Event items
are related. If you Enable the Traffic-Overload event, then be sure to enter a nonzero
Traffic-Threshold percentage, as well as a Traffic-Duration between 1 and 300 seconds.
Override Relay Warning Settings
Click the checkbox to override the relay warning setting temporarily. Releasing the relay output
will allow administrators to fix any problems with the warning condition.
Relay Warning List
Use this table to see if any relay warnings have been issued.
Using Line-Swap-Fast-Recovery
The Line-Swap Fast Recovery function, which is enabled by default, allows the EDS to return to
normal operation very quickly after devices are unplugged and then re-plugged into different ports.
The recovery time is in the order of a few milliseconds. Compare this with standard commercial
switches for which the recovery time could be in the order of several minutes. To disable the
Line-Swap Fast Recovery function, or to re-enable the function after it has already been disabled,
access either the Console utility’s Line-Swap recovery page, or the Web Browser interface’s
Line-Swap fast recovery page, as shown next.