Multi-Tech Systems MVP210/410/810 Server User Manual


 
Technical Configuration (Analog/BRI) MultiVOIP User Guide
244
FXS Loop Start Interface: Parameter Definitions (cont’d)
Field Name Values Description
Dialing Options fields
Inter Digit
Timer
1 - 10 seconds This is the length of time that
the MultiVOIP will wait
between digits. When the time
expires, the MultiVOIP will
look in the outbound
phonebook for the number
entered and place the call
accordingly.
Default = 2.
Message
Waiting
Indication
-- Not applicable to FXS Loop
Start interface
Inter Digit
Regeneration
Time
in milliseconds
The length of time between the
outputting of DTMF digits.
Default = 100 ms.
Ring Count,
FXS
1-99
Maximum number of rings that
the MultiVOIP will issue before
giving up the attempted call.
FXS Options,
Current Loss
Y/N
When enabled, the MultiVOIP
will interrupt loop current in
the FXS circuit to initiate a
disconnection. This tells the
device connected to the FXS
port to hang up. The Multi-
VOIP cannot drop the call; the
FXS device must go on hook.