National Instruments FP-PS-4 Power Supply User Manual


 
FP-PS-4 Operating Instructions 8 ni.com
6. Connect the green or green/yellow conductor into the ground
terminal.
Caution
When you install the conductors, make sure that
the entire conductor is in the screw terminal andthat there
are no loose strands outside of the terminal. Only install
one wire in each terminal.
Specifications
The following specifications are typical for a range of 0 to 60 °C,
unless otherwise noted.
Installation
Terminal wiring ................................16-26 AWG copper
conductor wire with 7 mm
(0.275 in.) strip length as
showninFigure8
Figure 8. ConductorWirewiththeCorrectStripLength(drawingistoscale)
Torque for screw terminals ...............0.5-0.6 Nm (4.45.3 in.-lbs)
Input Characteristics
Input voltage .....................................90264 VAC
Frequency .........................................4763 Hz, single phase
Maximum current consumption........ 0.6 A at 120 VAC, 60 Hz
Input protection.................................Nonreplaceable internal
AC fuse
Output Characteristics
Output voltage ..................................24 VDC, nonadjusting
Nominal current (I
N
).........................600 mA
Nominal continuous power
0to50°C ...................................15 W
50 to 60 °C .................................10 W
7mm