National Instruments MXI Personal Computer User Manual


 
Appendix B Common Questions
© National Instruments Corporation B-3 MXI-Express (x1) for PXI Express Series User Manual
NI PXIe-8360 includes five to seven bridges and one
NI PXIe-8360 SMBus Controller device.
If the MXI-Express software is not installed, the PCI-to-PCI function will
still be detected and work correctly, but the SMBus master will be detected
as an unknown device.
MXI-3 and MXI-4 to MXI-Express Upgrade Questions
What are some of the improvements from MXI-3 and MXI-4 to
MXI-Express?
MXI-Express incorporates the latest technology to include:
Support for PCI Express slots.
Support for PXI Express and CompactPCI Express chassis.
Improved error correction and handling for noisy or harsh
environments.
Improved mechanical connectivity.
Improved performance.
Support for two chassis from a single card in the host PC.
Can a MXI-3, MXI-4, and MXI-Express board be used together
directly?
No. MXI-3, MXI-4, and MXI-Express boards use different cable
connectors and cannot be connected together. Additionally, the
board-to-board communication protocols differ.
Can I use a MXI-3, MXI-4, and MXI-Express kit in the same
multichassis PXI system?
Yes. Different MXI kits can be intermixed to connect multiple PXI and
PXI Express chassis together. As mentioned previously, an individual
MXI-3 or MXI-4 board will not cable directly to a MXI-Express board.
MXI-3 and MXI-4 systems required the use of a specific boot ordering.
Is this a requirement with MXI-Express?
Yes. The requirements of the PCI bus still mandate that you must power-on
secondary PXI chassis before powering on the host PC when using
MXI-Express.