National Instruments NI 9236 Network Card User Manual


 
NI 9235/9236 20 ni.com
Specifications
The following specifications are typical for the range –40 to 70 °C
unless otherwise noted. The specifications are the same for the
NI 9235 and the NI 9236 unless otherwise noted.
Input Characteristics
Number of channels..........................8 analog input channels
Quarter-bridge completion
NI 9235.......................................120 Ω, 10 ppm/°C
max
NI 9236.......................................350 Ω, 10 ppm/°C
max
ADC resolution.................................24 bits
Type of ADC.....................................Delta-Sigma (with analog
prefiltering)
Sampling mode.................................Simultaneous
Internal master timebase (f
M
)
Frequency...................................12.8 MHz
Accuracy.....................................±100 ppm max