Example power requirement calculations
For an sbRIO-9602 with three installed board-only C Series modules,
20 mA total current through 3.3 V DIO pins, and 1 A of current through
5 V output, calculate the total power requirement as follows:
P
int
= 6.0 W
P
CSer
= 3.30 W
P
DIO
= 0.08 W
P
5V
= 5.55 W
Adding 20% for transient conditions, 14.93 W × 1.2 = 17.92 W
Total power requirement = 17.92 W
For an sbRIO-9601 with one installed board-only C Series module,
330 mA total current through 3.3 V DIO pins, and no 5 V output used,
calculate the total power requirement as follows:
P
int
= 6.0 W
P
CSer
= 1.10 W
P
DIO
= 1.28 W
P
5V
= 0.00 W
Adding 20% for transient conditions, 8.38 W × 1.2 = 10.06 W
Total power requirement = 10.06 W
Backup battery ....................................... 3 V lithium coin cell, BR2032
Working I/O Voltages
Connect only voltages that are within these limits.
V terminal to C terminal ........................ 35 VDC max,
Measurement Category I
Caution Do not connect the system to signals or use for measurements within
Measurement Categories II, III, or IV.