Appendix A Specifications
© National Instruments Corporation A-3 NI SPEEDY-33 User Manual
Physical
PCB only
Dimensions ..................................... 8.89 cm × 12.7 cm × 1.91 cm
(3.5 in. × 5 in. × 0.75 in.)
Weight.............................................87.9 g (3.1 oz)
With enclosure
Dimensions .....................................11.1 cm × 14.5 cm × 3.9 cm
(4.4 in. × 5.7 in. × 1.5 in.)
Weight.............................................380 g (12.8 oz)
USB connector....................................... Type B USB port, conforms to
USB Specification 1.1
Connector...............................................Standard mini stereo jack
I/O connectors
J1, J2, J5, J12 ..................................0.10 in. × 0.10 in. × 0.23 in.
in 1 × 3 rows
J4.....................................................0.10 in. × 0.10 in. × 0.23 in.
in 2 × 5 rows
J6, J11 .............................................0.10 in. × 0.10 in. × 0.23 in.
in 2 × 10 rows
Environmental
The NI SPEEDY-33 device is intended for indoor use only.
Operating temperature............................ 0 to 55 °C
Storage temperature ...............................–20 to 70 °C
Humidity ................................................ 10 to 90% RH, noncondensing
Maximum altitude..................................2,000 m
Pollution Degree ....................................2
If you need to clean the module, use a soft, nonmetallic brush. Make sure
that the module is completely dry and free from contaminants before