NEC N8800-090F Server User Manual


 
7-10 Troubleshooting
On-screen error message Cause Action
9027 Mounted CPU is
mismatching.
CPU configuration may be
different between the CPU/IO
modules.
Replace the CPU.
If this does not help, replace the
CPU/IO module.
9028 Memory of the different types
is installed.
Memory of the different types is
installed.
Replace DIMM with appropriate
one.
If this does not help, replace the
CPU/IO module.
9029 DIMM is faulty. Replace DIMM.
If this does not help, replace the
CPU/IO module.
902A Initialization of the cross-link
between the CPU/IO modules
and access are faulty.
When the system is running in
the duplex mode, it is no
problem.
If the system cannot be running
in the duplex mode due to
continuous this error, replace the
CPU/IO module.
If this does not help, replace
another CPU/IO module or
center plane.
902B BIOS revision does not
match.
This BIOS revision cannot
support the duplex mode.
Update the BIOS revision.
9031 Configuration of PCI riser is
mismatch.
Check the PCI configuration.
If this does not help, replace the
CPU/IO module.
9032 The microcode to CPU is not
found and it cannot update
normally.
Unsupported CPU may be
mounted.
Replace the CPU.
If this does not help, replace the
CPU/IO module.
9033 The microcode to CPU
cannot update normally.
Replace the CPU.
If this does not help, replace the
CPU/IO module.
9034 DIMM is faulty. Replace the DIMM.
If this does not help, replace the
CPU/IO module.
903A DIMM is faulty. Replace the DIMM.
If this does not help, replace the
CPU/IO module.
9040 - 9047 CPU is faulty. (ID=0-7) Replace the CPU.
9050 - 9055 DIMM is faulty. (ID=0-5) Replace the DIMM.
If this does not help, replace the