NETGEAR FS 524S Switch User Manual


 
C-5cabling guidelines
Patch Panels and Cables
If you are using patch panels, make sure that they meet the 100BASE-TX requirements.
NETGEAR recommends Category 5 UTP cable for all patch cables and work area
cables to ensure that your UTP patch cable rating meets or exceeds the distribution
cable rating.
To wire patch panels, you need two Category 5 UTP cables with an RJ-45 plug at each
end, as shown in Figure C-3.
Figure C-3. Category 5 UTP Cable with Male RJ-45 Plug at Each End
Note: Flat silver satintelephone cable may have the same RJ-45 plug.
However, using telephone cable results in excessive collisions, causing the attached
port to be partitioned or disconnected from the network.
Using 1000BASE-T Gigabit Ethernet over Category 5 Cable
Overview
When using the new 1000BASE-T standard, the limitations of cable installations and
the steps necessary to ensure optimum performance must be considered.The most
important components in your cabling system are patch panel connections, twists of the
pairs at connector transition points, the jacket around the twisted-pair cable, bundling
of multiple pairs on horizontal runs and punch down blocks. All of these factors affect
the performance of 1000BASE-T technology if not correctly implemented.The follow-
ing sections are designed to act as a guide to correct cabling for 1000BASE-T.
87654321
87654321
2 1
1