NETGEAR DS104 Switch User Manual


 
Model DS104/DS106/DS108/DS116 Dual Speed Hub Installation Guide
Before you begin installing the hub, prepare the installation site. Make sure the
site meets the operating environment requirements of the equipment.
Install the Hub on a Flat Surface
If installing the hub on a at surface such as a tabletop, make sure the bottom of
the chassis is clean and dry.
To install the hub on a at surface:
1. Set the hub on a table or shelf so that it has at least 2 inches (5 cm) of
space on all sides.
2. Connect the power cord(s) first to the power entry receptacle on the
hub rear panel and then to the wall.
Install the Hub on a Wall
If installing the hub on a wall, make sure you have a Phillips screwdriver.
To install the hub on a wall:
1. Set the mounting screws and anchors (supplied with the wall mount
hardware) in the wall.
2. Using the slots on the bottom of the hub, hang the hub on the wall.
3. Connect the power cord(s) first to the power entry receptacle on the
hub rear panel and then to the wall.
Characteristic
Requirement
Temperature
Ambient temperature between 0
°
and 40
°
C
(32
°
and 104
°
F). No nearby heat sources such as direct sunlight,
warm air exhausts, or heaters.
Humidity 90% maximum relative humidity, noncondensing.
Ventilation Minimum 2 inches (5.08 cm) on all sides for cooling.
Adequate airow in room or wiring closet.
Operating
conditions
At least 6 feet (1.83 m) to nearest source of electromagnetic noise
(such as photocopy machine or arc welder).
Service access Minimum 12 inches (19.68 cm) front and back for service access and
maintenance.
Front and back clearance for cables and wiring hardware such as
punchdown blocks.
Power Adequate power source within 6 feet (1.83 m).
Wiring hardware Wiring hardware, such as punchdown blocks or patch panels,
complete before installing the hub.
Installation Procedures
Prepare the Site
Install the Hub