Nortel Networks CTA 500dm Modem User Manual


 
AT commands 41
P0873832 Issue 05 CTA 500
dm
On Line Guide
Call Monitoring Result Code Selection
The Call Monitoring Result Code Selection Command
X[value]
controls the format of result codes sent by the CTA 500dm in
verbose mode during call setup. (See possible values in the
following table.) Values 1 and 2 are identical since the CTA 500dm
does not support dial tone detection.
Result Codes
OK Appears when the value is acceptable.
ERROR Appears when the value is unacceptable.
S-registers
The S-registers allow you to control CTA 500dm operation. The
registers are usually both read and write accessible. The registers
used vary with the application supported by the CTA 500dm. All
S-registers are saved as part of a CTA 500dm proÞle. S-registers can
appear as a group by using the &V command (see ÒGeneralÓ on
page 35 for more information).
S-register commands summary
Value Result Code Operation
0 connect result code, no busy detection
1 connect rate result code, no busy detection
2 connect rate result code, no busy detection
3 connect rate result code, busy detection
4 connect rate result code, busy detection (default)
Command Description Value
Sn= set value to S-register depends on register
Sn? query S-register value