Nortel Networks CTA 500dm Modem User Manual


 
AT commands 43
P0873832 Issue 05 CTA 500
dm
On Line Guide
S-register set
The following table shows the complete S-register set for the
CTA 500dm. Not all options are supported for all versions of the
CTA 500dm.
Register Description Value
S0 number of rings until answer 0-255 (default 1)
S1 ring count (read only) 0-255 (default 0)
S2 escape character 0-127 (default 43)
128-255 (disables escape
sequence)
S3 carriage return character 0-127 (default 13)
S4 line feed character 0-127 (default 10)
S5 back space character 0-127 (default 8)
S7 wait for connection 1-255 in seconds (default 30)
S10 DCD drop time 1-255 in tenths of a second
(default 14)
S12 guard time 0-255 in fiftieths of a second
(default 50)
S25 DTR detect time 0-255 in hundredths of a
second (default 5)
S26 RTS to CTS time 0-255 in hundredths of a
second (default 1)