N-Tron 102PC-SE Network Card User Manual


 
Rev. 041008
26
SNTP General
SNTP Client: Enables/Disables the SNTP Client to contact the configured server on UDP port 123 and set the local time
Default:
disable
Server Name: Sets the NTP server name or IP address to which the SNTP Client has to contact to update the time
Default:
127.0.0.1
Time Zone: Sets the time zone
Default:
UTC
Time Zone offset: Sets the offset time from UTC
Default:
+00:00 (+/-hh:mm)
Polling Time: Sets the polling time at which SNTP client requests the server to update the time
Default:
300 minutes
Daylight Saving: Enables/Disables the Day Light Saving Mode
Default:
enable
Daylight Saving offset: Sets the offset to use during the Day Light Saving Mode
Default:
+60 (+/-mm)
SNTP Daylight Saving Configuration
Start Ordinal: Sets the start ordinal to use during the Day Light Saving Mode. Options - first/second/third/forth/last
Default:
first
End Ordinal: Sets the last ordinal to use during the Day Light Saving Mode. Options - first/second/third/forth/last
Default:
last
Start Month: Sets the start month to use during the Day Light Saving Mode
Default:
april
End Month: Sets the end month to use during the Day Light Saving Mode
Default:
october
Start Day: Sets the start weekday to use during the Day Light Saving Mode
Default:
sunday
End Day: Sets the end weekday to use during the Day Light Saving Mode
Default:
sunday
Start Time: Sets the start time to use during the Day Light Saving Mode
Default:
02:00 (hh:mm)
End Time: Sets the end time to use during the Day Light Saving Mode.
Default:
02:00 (hh:mm)
Commands
User can enter any "set" commands as per the manual
View Statistics
Bridge: Displays the Bridge Statistics only when bridge is enabled
eth0: Displays Ethernet Statistics
serial: Displays Serial Statistics
PPP: Displays PPP Statistics only when PPP is enabled
Users: Displays the Default and Added users of the module
System Information: Displays the System information of the module. Processor details, Uptime, Memory utilization, Flash Memory map, Version, Date,
Binary details
Save
Upon clicking Save button, it prompts for confirmation
If selected OK, the modified configuration is written into flash and if the box may reboot for few configuration changes. After few seconds, the
default.html/http-s0.html page will be launched again as per configuration. If the page is not launched, check the IP address and HTTP configuration status
If selected CANCEL, the browser is redirected to General Configuration page
Restore Defaults
Upon clicking Restore Defaults button, it prompts for confirmation
If selected OK, the configuration is restored to factory defaults and redirected to General Configuration page. User need to click save button to save the
configuration
If selected CANCEL, the browser is redirected to General Configuration page