N-Tron 604MFX-ST Switch User Manual


 
12/15/05
14
“Select/Set” Button
The Select/Set” multi-functional button on the front panel of the
604/608MFX performs the following actions:
Pressing the button briefly (similar to left mouse click)
transitions the display of the two display mode LED’s. The
current display mode is indicated by the status of the display
mode LED’s per the legend definition on the front of the
swtich.
If the Display Mode is currently selecting port status (all
Display Mode LEDs off) and if the button is pressed for three
seconds, the Display Mode LEDs begin to flash. If you then
continue to press the button for a further two seconds, the
switch is reset. When the 600 series switch is reset, all the
settings return to their defaults (as set in the factory). This
allows you to cancel settings made from the Web based
management tools, Telnet, or the command line configurator
(serial port), or the fault mask.
If the Display Mode is currently selecting the fault status and
you press the button for two seconds, the display LED’s start
to flash. If you then continue pressing the button for another
two seconds, the current status of the ports and the supply
voltage are entered in the fault mask. Any change in their
status after the fault mask update will create a fault.
Note: Do not press the “Select/Set” button while the unit is powering up. In
the event that the “Select/Set” button was pressed while the switch is
starting up (approximately a 20-second window), all display mode LEDs
will flash simultaneously. This mode is exited by pressing the button again
after the unit has completely powered up (a 20-second delay).