Omega Speaker Systems DRX-TC All in One Printer User Manual


 
IV. COMMANDS FOR ACCESSING EEPROM:
NO. command letter index meaning # of bytes
1. R,W 01 Input range or function 1
2. R,W 02 Input/output Configuration 1
3. R,W 03 Decimal point 1
4. R,W 04 Filter time constant 1
5. R,W 05 Reading scale 3
6. R,W 06 Reading offset 3
7. R,W 07 Communication parameters 1
8. R,W 08 Communication bus format 1
9. R,W 09 Communication Data format 1
10. R,W 0A Communication device address 1
11. R,W 0B Communication recog. char. 1
12. R,W 0C Unit of measure 3
13. R,W 0D Gate time 1
14. R,W 0E Debounce time 1
15. R,W 0F Transmit time 2
NOTE:
1. Data (Number of hex digits) = 2 * number of bytes
2. command letter
meaning
R Read from EEPROM
W Write to EEPROM
3. "W" commands should be followed by "Z01" command for new values to take ef
fect.
A. COMMAND FORMAT (TRANSMITTING):
*[nn]Cxx[data][hh]<cr>
Note:
Data is required if Command Letter is “W”
B. RESPONSE FORMA
T (RECEIVING):
A. Correct response :
1. If unit is in echo mode
* (see "BUS FORMAT") :
[nn]Cxx[data][hh]<cr>
*echo mode = unit will send back the command.
Page 6