Omega Speaker Systems DRX-TC All in One Printer User Manual


 
?ee : Special code indicating an error has occurred as:
?43 : Command error
( occurs if command letters and indexes are invalid)
?46 : Format error
( occurs if length of the data or number of characters is not correct )
?48 : Checksum error
( occurs if checksum is not correct )
?50 : Parity error
( occurs if parity is not correct )
<cr> : Carriage return
Note:
If Baud rate, Recognition character or address are not correct then the UNIT will not
respond.
V. DESCRIPTION OF DATA :
For the following Bit Pattern. The LSB is always bit 0. Bit numbers are always counted from
right to left, with the rightmost digit being bit 0, and the next to the left would be bit 1.
1. INPUT RANGE:
This is one byte data (2 characters). This byte will specify input range and other input
configurations of each model. Bit pattern for different models :
a. INPUT RANGE BYTE VALUE TC ACV ACC
Bits:3210
0000 J 400 mV ac 10 mA
0001 K 4 V ac 100 mA
0010 T 40 V ac 1 A
0011 E 400 V ac 5 A
0100 N ---- ----
0101 DIN J ---- ----
0110 R ---- ----
0111 S ---- ----
1000 B ---- ----
(1001-1111 not used )
Bit 6-4: not used
Bit 7: 0 Line frequency = 60Hz
1 Line frequency = 50Hz
Page 8