Omega OME-A822PG Computer Hardware User Manual


 
5. Diagnostic Utility
5.1 Introduction
The A82XDIAG.EXE diagnostic utility is a menu-driven program which allows
complete testing of the OME-A-822PGL/PGH board. To run the diagnostic utility,
change to the subdirectory used in the installation process (C:\OME-A-822 for example).
Then type "A82XDIAG" <Enter> to start the application. These steps are shown
below:
C:\>CD A822<Enter>
C:\A822>CD DIAG <Enter>
C:\A822\DIAG>A82XDIAG <Enter>
A configuration file, named OME-A-82X.CFG is associated with the
A82XDIAG.EXE program. The configu ration of the OME-A-822PGL/PGH board
is stored in this file. The stored information includes the board's I/O base address, interrupt
number and DMA channel. Changes are not automatically saved to the configuration file,
the user must select the save function to save any changes. When the
A82XDIAG.EXE utility starts, it will automatically check if the jumper setting of
the I/O base address matches the value stored in the configuration file. If the addresses do
not match, an error message will appear as shown below.
OME-A-822PGL/PGH Hardware Manual ---- 44