Opticon
OPR 2001
Specifications Manual
33
10.3. Default Settings 2: Read Options, Trigger, Buzzer
Item Default Setting
Setting the number of characters Fixed length OFF all codes
Read mode Single read
Multiple read reset time 500 ms
Add-on wait time 500 ms
Multiple columns read Disabled
Default option
([X0] setting)
Read 1 times, redundancy = 0
Redundancy
Other options
([X1 .. X3] setting)
([BS .. BW] setting)
Read n times, redundancy = n+1
for following symbologies and lengths:
● Code39 with length <= 5
● MSI/Plessey with length <= 4
● IATA,Industrial 2of5, Interleaved 2of5
with length <= 8
● Matrix 2of5 (& Chin.Post), Scode
with length <= 8
● Codabar (NW7) with all lengths
● Code-11 with length <= 5
Trigger switch Enabled
Trigger repeat Disable trigger repeat
Auto trigger Disable auto trigger
Margin check Margin check normal
Buzzer duration 50 ms
Buzzer tone 3 kHz (single tone)
Buzzer loudness Loud (Maximum)
Buzzer timing Buzzer before transmission
Startup buzzer Enable startup buzzer
Indicator duration 200 ms