Panamax MAX 5510 Power Supply User Manual


 
10 1690 Corporate Circle, Petaluma, CA 94954 • www.panamax.com
FEATURE DETAILS
Protect or Disconnect™ AC Surge Protection
When the MAX® 5510 ACRegenerator™ is subjected to a high voltage surge, voltage output is limited to a safe level and the
high levels of surge current are diverted away from the connected equipment.
• When subjected to a 6,000V (open circuit voltage) / 500A (short circuit current) surge, the MAX
® 5510 limits
voltage output to less than 330V peak, UL’s lowest rating. The MAX
® 5510 will withstand without damage,
multiple 12,000A surges, far exceeding the UL maximum requirement of only 3,000 Ampere surges.
• If the magnitude of the surge is greater than the capacity of the surge protection components, the MAX
® 5510’s
Protect or DisconnectCircuitry will disconnect your equipment in order to protect it. The MAX® 5510 will need
to be repaired or replaced by Panamax if this occurs.
SurgeGate Plus™ Protection
The MAX® 5510 constantly monitors the AC line voltage for unsafe voltage conditions such as prolonged overvoltages and
undervoltages (brownouts). These unsafe conditions pose a very dangerous threat to all electronic equipment within the
home. If the MAX® 5510 senses an unsafe power condition, it will automatically disconnect your equipment from the power
to protect equipment from damage. Once the voltage returns to a safe level, the MAX
® 5510 will automatically reconnect
the power.
If the line voltage exceeds the overvoltage threshold (137VAC) or falls below the undervoltage threshold (95VAC), the MAX
®
5510 will perform the following tasks until line voltage returns to a safe level:
1. Disconnects power to all connected equipment.
2. Unsafe Voltage LED is activated and will blink once per second during the unsafe voltage condition.
The MAX
® 5510 requires line voltage to return to within the safe operating range for 10 seconds before returning to normal
operating mode. This is referred to as “Over/Undervoltage Recovery”. The safe operating range is considered 5V above the
under-voltage threshold (~100V) and 5V below the overvoltage threshold (~132V). Once this safe operating range is reached,
the MAX® 5510 will perform the following functions:
1. Unsafe Voltage LED will blink 4 times per second for Over/Undervoltage Recovery.
2. Power is restored to all connected equipment after the 10-second delay. The normal start-up sequence as deter-
mined by the “High-Current Outlets Turn-On Switch” and “Isolated Outlets Turn-Off Switch” will be followed.
1. Voltage reaches an unsafe level.
2. If surge is greater than MAX
®
5500 capacity, it disconnects.
1. Voltage reaches an unsafe high
level and the SurgeGate Plus™
disconnects.
2. Voltage reaches a safe level and
SurgeGate Plus™ automatically
reconnects.
3. Voltage reaches an unsafe low level
and SurgeGate Plus™ disconnects.
4. Voltage reaches a safe level and
SurgeGate Plus™ automatically
reconnects.
The MAX® 5510 provides protection against common problems on the AC power line. This includes spikes/surges and sus-
tained overvoltages or undervoltages. Panamax’s exclusive Protect or Disconnect™ circuitry is designed to protect against
spikes/surges while the SurgeGate Plus™ circuitry is for sustained over/under voltage protection.