S PEC F ILE
PT-DW6300S/DW6300K/DW6300LS/DW6300LK
DLP
™
Projectors
As of February 2009 < 12 >
Control commands
Command :Parameter Function Callback
PON
POF
IIS:DVI
IIS:RG1
IIS:RG2
IIS:VID
IIS:SVD
LPM:0
LPM:1
LPM:2
LPM:3
OSH:0
OSH:1
OFZ:0
OFZ:1
OAS
VPM:NAT
VPM:STD
VPM:DYN
VPM:CIN
VPM:GRA
VXX:DLVI0=+00000
VXX:DLVI0=+00001
VXX:DLVI0=+00002
VXX:DLVI0=+00003
OTE:1
OTE:2
OTE:4
OTE:10
TSD:y1y2y3y4m1m2d1d2w
TST:h1h2m1m2s1s2
OOS:0
OOS:1
Standby power on
Standby power off
DVI
RGB 1
RGB 2
Video
S-VideoAUX
Dual (two lamps)
Lamp 1
Lamp 2
Single lamp
Shutter on
Shutter off
Off
On
Natural
Standard
Dynamic
Cinema
Graphic
Off
1
2
3
Middle
High
User
Default
Date setting
Time setting
On-screen display on
On-screen display off
POWER (STANDBY)
INPUT SELECT
LAMP SELECT
SHUTTER
FREEZE
AUTO SETUP
PICTURE MODE
SYSTEM DAYLIGHT VIEW 2
COLOR TEMPERATURE
DATE
TIME
ON SCREEN
PON
POF
IIS:DVI
IIS:RG1
IIS:RG2
IIS:VID
IIS:SVD
LPM:0
LPM:1
LPM:2
LPM:3
OSH:0
OSH:1
OFZ:0
OFZ:1
OAS
VPM:NAT
VPM:STD
VPM:DYN
VPM:CIN
VPM:GRA
VXX:DLVI0=+00000
VXX:DLVI0=+00001
VXX:DLVI0=+00002
VXX:DLVI0=+00003
OTE:1
OTE:2
OTE:4
OTE:10
TSD:y1y2y3y4m1m2d1d2w
TST:h1h2m1m2s1s2
OOS:0
OOS:1
Cable specifications
1
2
3
4
5
6
7
8
9
1
2
3
4
5
6
7
8
9
PC (DTE)Projector
NC
NC
NC
NC
NC
NC
NC
NC
* Do not send PON, POF, OSH, or OLP commands continuously in a short period of time. Doing so may burst the lamp or shorten the lamp
replacement cycle.
* When a command that cannot be executed during standby mode is sent, the projector will send an ER401 command in reply.