3. Remove the double feed prevention roller.
While pushing the latch (A) to the right side as the direction indicated by the arrow, remove the double
feed prevention roller (B) in the direction of the arrow. Then, pull out the left shaft (when facing it) from
the notch in the roller mount.
2
1
4. Take out the new double feed prevention roller module in the optional roller exchange kit.
5. Install the double feed prevention roller.
Align the shaft that is shaped as indicated by A with the notch in the roller mount (B), and then insert
the shaft in the notch. Push the shaft on the opposite side (C) until it clicks into place.
3
2
1
Operating Manual 61
Care and Maintenance