Chapter 6 Appendix — Technical information
142 - ENGLISH
<SERIAL IN> terminal
The <SERIAL IN> terminal of the projector conforms with RS-232C so that the projector can be connected to and controlled from a computer.
Connection
LAN cable (straight)
Communication cable (straight)
D-Sub 9p (male)
D-Sub 9p (female)DIGITAL LINKDIGITAL LINK
Computer
DIGITAL LINK compatible deviceProjector connecting terminals
When connecting with DIGITAL LINK compatible devices
Communication cable (straight)
D-Sub 9p (male)
D-Sub 9p (female)
Computer
Projector connecting terminals
When connecting directly
Note
f The destination of [RS-232C] (x page 92) must be set according to the connection method.
f When connecting by a DIGITAL LINK compatible device, set the [PROJECTOR SETUP] menu → [ECO MANAGEMENT] → [STANDBY
MODE] (x page 90) to [NORMAL] to control the projector in standby mode.
When [STANDBY MODE] is set to [ECO], the projector cannot be control during standby.
Pin assignments and signal names
D-Sub 9-pin (female)
Outside view
Pin No. Signal name Details
(9) (6)
(5) (1)
(1) ― NC
(2) TXD Transmitted data
(3) RXD Received data
(4) ― NC
(5) GND Earth
(6) ― NC
(7) CTS
Connected internally
(8) RTS
(9) ― NC
Communication conditions (Factory default)
Signal level RS-232C-compliant
Sync. method Asynchronous
Baud rate 9 600 bps
Parity None
Character length 8 bits
Stop bit 1 bit
X parameter None
S parameter None