Panasonic PT-VX500U Projector User Manual


 
Network
66
- ENGLISH
Settings
Error information page
J
If [Error (Detail)] is displayed in the self-diagnosis information display column on the [Projector status] screen,
click the part to display the details of the error.
Depending on the nature of the error, the projector may be placed in the standby mode for its own protection.
When [FAILED] has appeared for an item
Parameter Description
FAN Trouble has occurred in the fan or its drive circuit. Consult your dealer.
INTAKE AIR TEMPERATURE
Intake air temperature is high. It could be because it is used in an environment of high
temperature such as close to a heating device, etc., the air intake is blocked, or the air
lter is clogged.
EXHAUST AIR TEMPERATURE
Exhaust air temperature is high. Exhaust may be blocked, or [Fan control] mode may
be set wrong. (
Æ
page 57)
OPTICS MODULE TEMPERATURE Optics module temperature is high.
LAMP REMAIN TIME
The lamp runtime has exceeded the prescribed cumulative time, and it is now time to
replace the lamp.
LAMP STATUS
The lamp has failed to light.
Wait a short while for the lamp to cool off, and then turn on the power.
APERTURE (CONTRAST-SHUTTER) Trouble has occurred in the contrast shutter circuitry. Consult your dealer.
OK: Normal operation
FAILED: Occurrence of trouble
WARNING: Abnormal condition
Network status page
J
Displays the current conguration information of the network.
Displays the conguration details of wired LAN.